AND BP Monitor
Irregular HeartBeat Indicator
The indicator illuminates if an IHB is detected during the measurement. The indicator alerts users of an irregular heartbeat, which may be associated with cardiovascular disease. (Note: This is for warning purposes only. A&D recommends contacting a physician if the user observes this indicator frequently.)
Blood Pressure Classification Indicator
The World Health Organization (WHO) has designated 6 blood pressure classifications. This monitor automatically indicates your classification (Optimal to Severe hypertension) after each measurement is completed.
180~ |
110~ |
Grade 3 hypertension (severe) |
160~179 |
100~109 |
Grade 2 hypertension (moderate) |
140~159 |
90~99 |
Grade 1 hypertension (mild) |
130~139 |
85~89 |
High–normal |
120~129 |
80~84 |
Normal |
Less than 120 |
Less than 80 |
Optimal |
Blood Sugar Meter
Precision
· Obtained the same results from one strip vial.
· Evaluation parameter : coefficient of variation (CV)
· Single vial: CV(%) < 3
· Competitors’ Standard: CV(%) < 5
Accuracy
· Obtained correct results.
· Evaluation parameter : EGA plot
· Accuracy : ±15%
· Competitors’ Standard: ±20%
Strip
· Friendly & Flexible Design
· Custom-made design capability
· High quality hydrophilic layer printing
Meter
· Reliable TI (Texas Instrument) micro-controller
· Accurate Temperature compensation scheme
· Unique voltage pattern
Clinical Trial
· Excellent results from first-tier hospital of Taiwan
· Protocol followed FDA guideline
· Complete 19 interferences clinical tests
Fast
· Fast Blood Draw-in Strip Design
· Fast 5 Seconds Testing Time.
Easy
· Easy Large Display
· Easy small 0.8µL Blood Needed, painful
· Data Dwnload Capability to PC
· Build in 7,14,28 Average
DiaCheck Kit Content
· DiaCheck Blood Glucose Meter
· DiaCheck Blood Glucose Test Strips*10
· Lancing Device
· Lancets * 10
· Quick Reference Guide
· User Guide /Log book
· Discreet Carrying Case
p<· Warrannty Card
BD-1250 Thermometer
TechnicalSpecification
|
Measurement range |
89.6°F ~ 109°F |
Resolution |
0.1°F |
Accuracy |
±0.1°F (95°F to 107.6°F) |
Display |
Liquid Crystal Display |
Battery |
Micro Alkaline battery 1.55V (SR41, UCC392 or LR41) |
Power Consumption |
0.15 illiwatts in measurement mode |
Battery Life |
More than 200 hours of continuous operation |
Beeper |
Approx. 10-second sound signal when peak temperature reached |
SlimFit Comfortable Cuff (UA-621)
During a measurement, our new innovative edge free internal bladder “EFB” distributes pressure evenly around the user’s arm. This provides a higher level of comfort while the arm is under pressure.
Fully Automatic Measurement
Pressing the START button is the only step necessary to perform a complete and accurate measurement.
Large 30-Memory + Average Reading
30-reading memory capacity for monitoring your measurement trends. An average of all the stored data is shown at the start of each measurement, offering the user their comprehensive measurement history at a glance.
Standard AC adapter Inlet (UA-621)
The monitor is equipped with an AC inlet for use with an external power source. Since there is no need to worry about battery life, the user can economize while enjoying the use of the monitor everyday. (The AC adapter is optional and should be bought separately.)
Blood Sugar Meter
· Measuring range: 20~600mg/dL (1.1 mmol/L ~ 33.33 mmol/L )
· Measuring time: 5 seconds
· Blood Sample size: 0.8?L
· Memory capacity: Up to 512 test results (included date, time and unit)
· Average results for the last 7, 14 or 28 days
· Auto power on & off
· USB Data Download Capacity
· Temperature Compensation
BD-1250 Thermometer